Written radiation protection program
Ohio requires each handler of non-medical radiation-generating equipment to develop, implement, and maintain a written radiation protection program covering the subjects specified by rule.
OAC 3701:1-68-02 ↗A practical overview of verified and qualified Ohio requirements for facilities that operate covered non-medical cabinet X-ray systems.
Ohio requires each handler of non-medical radiation-generating equipment to develop, implement, and maintain a written radiation protection program covering the subjects specified by rule.
OAC 3701:1-68-02 ↗Covered Ohio facilities generally must apply for registration before handling radiation-generating equipment. RayReg preserves the exemptions in the rule rather than treating registration as unconditional.
OAC 3701:1-38-03 ↗Cabinet-system operators must receive training and demonstrate competence in the cabinet-specific topics in paragraph (H). Importantly, ordinary cabinet operators are exempt from paragraphs (C), (D), and (E), so RayReg does not automatically apply the general annual radiographic refresher interval.
OAC 3701:1-68-02(H) ↗Covered cabinet systems must be evaluated and results recorded every three months, not to exceed fourteen weeks, subject to the rule's lockout exception.
OAC 3701:1-68-06(D) ↗Recorded radiation-area surveys are triggered at installation, during specified primary-beam maintenance/calibration procedures, and when visual inspection reveals an abnormal cabinet condition.
OAC 3701:1-68-06(E) ↗Ohio limits radiation emitted from a cabinet system to 4.4 microgray (0.5 milliroentgen) in one hour at any point five centimeters outside the external surface.
OAC 3701:1-68-06(A)(1) ↗Focused articles explain the facility-level questions behind registration, training, recurring evaluations, survey triggers, records, and failed safety devices.